The selection of solenoid valves requires careful consideration.

Release Date:

2026-08-26

Author:

Kangleda New Energy


Abstract

In principle, solenoid valves are classified into three major types: direct‑acting, step‑direct‑acting, and pilot‑operated. Furthermore, based on differences in the valve disc’s structure and materials as well as variations in their operating principles, they can be further subdivided into six minor categories.

In principle, solenoid valves are classified into three main types: direct‑acting, step‑direct‑acting, and pilot‑operated. Based on differences in valve‑disc design and materials, as well as variations in operating principles, they are further subdivided into six subcategories: direct‑acting diaphragm type, step‑direct‑acting diaphragm type, pilot‑operated diaphragm type, direct‑acting piston type, step‑direct‑acting piston type, and pilot‑operated piston type.

1. Indirect Pilot-Operated Solenoid Valve

This type of solenoid valve is composed of a pilot valve and a main spool connected to form a flow path; the normally closed version remains shut when de‑energized. When the coil is energized, the resulting magnetic force pulls the moving and stationary iron cores together, opening the pilot port and allowing the medium to flow toward the outlet. At this point, the pressure in the upper chamber of the main spool drops below the inlet pressure, creating a pressure differential that overcomes the spring force and drives the spool upward, thereby opening the main port and permitting flow. When the coil is de‑energized, the magnetic force disappears, and the moving core returns to its original position under spring force, closing the pilot port. Simultaneously, the medium flows through the balance hole, increasing the pressure in the upper chamber of the main spool, which then moves downward under spring force to close the main port. The normally open configuration operates on the opposite principle.

Principle: When energized, the electromagnetic force opens the pilot port, causing a rapid drop in pressure in the upper chamber and establishing a pressure differential—low pressure above and high pressure below—around the valve plug. The fluid pressure then pushes the plug upward, opening the valve. When power is off, spring force closes the pilot port, allowing inlet pressure to quickly equalize through the bypass passage and creating a pressure differential—high pressure above and low pressure below—around the valve plug. The fluid pressure then drives the plug downward, closing the valve.

Features: compact size, low power consumption, a relatively high upper limit for fluid pressure, and flexible installation options (customization required), provided that the specified fluid pressure differential is met.

2. Step-type direct-acting solenoid valve

This type of valve integrates primary and secondary opening functions into a single unit. The main valve and the pilot valve operate in sequence, with electromagnetic force and pressure differential directly opening the main valve port. When the coil is energized, electromagnetic force causes the moving and stationary iron cores to attract, opening the pilot valve port; the pilot valve port is positioned above the main valve port, and the moving core is connected to the main valve spool. At this point, the pressure in the upper chamber of the main valve is relieved through the pilot valve port, and under the combined action of the pressure differential and electromagnetic force, the main valve spool moves upward, allowing the medium to flow. When the coil is de-energized, the electromagnetic force disappears, and the moving core, acted upon by gravity and spring force, closes the pilot valve port. Meanwhile, the medium enters the upper chamber of the main valve spool via the balance hole, raising the pressure in that chamber. Under the spring’s return force and the resulting pressure, the main valve closes, shutting off the medium flow. The design is well‑structured and operationally reliable, even at zero pressure differential. Examples include models such as ZQDF, ZS, and 2W.

Principle: This valve operates on a combined direct‑acting and pilot‑operated principle. When there is no pressure differential between the inlet and outlet, energization causes the electromagnetic force to lift the pilot spool and the main valve plug sequentially, opening the valve. Once the inlet–outlet pressure differential reaches the actuation threshold, energization activates the pilot valve, causing the pressure in the lower chamber of the main valve to rise while the upper chamber pressure drops; the resulting pressure differential then pushes the main valve upward to open. Upon de‑energization, the pilot valve, aided by spring force or system pressure, drives the closing element downward, thereby sealing the valve.

Features: It can operate under zero differential pressure, vacuum, or high-pressure conditions; however, it has relatively high power consumption and must be installed horizontally.

3. Direct-acting solenoid valve

There are two types: normally closed and normally open. In the normally closed type, the valve remains closed when de-energized; when the coil is energized, electromagnetic force overcomes the spring force, causing the moving armature to attract the stationary armature and directly open the valve, allowing flow. When the coil is de-energized, the electromagnetic force disappears, and the moving armature returns to its original position under spring force, directly closing the valve and stopping flow. This design is simple and reliable, operating normally under zero differential pressure and in low vacuum conditions. The normally open type operates in the opposite manner. Examples include solenoid valves with a nominal diameter of less than φ6.

Principle: In a normally closed valve, when energized, the solenoid coil generates electromagnetic force to lift the poppet off the seat, opening the valve; when de-energized, the electromagnetic force is lost, and the spring presses the poppet against the seat, closing the valve. (A normally open valve operates in the opposite manner.)

Features: It can operate normally under vacuum, negative pressure, and zero pressure conditions, but its nominal diameter generally does not exceed 25 mm.

IV. The Difference Between Solenoid Valves and Electrically Operated Valves
Solenoid valve

An electric valve uses an electric motor to drive the valve stem, which in turn actuates the valve plug to either allow or shut off fluid flow. A solenoid valve consists of a solenoid coil (electromagnet), a valve plug, and a valve body; when the solenoid coil is energized or de-energized, it moves the valve plug, thereby permitting fluid to pass through the valve body or blocking the flow.

Electric valves are not only suitable for controlling common fluid media, but are especially well-suited for handling pulp, wastewater, and media containing fibers and fine solid particles. They impose relatively low requirements on the cleanliness of the medium, though their leakage rate is somewhat higher than that of solenoid valves.

Electric valves are typically driven by electric motors, which offer excellent resistance to voltage surges and deliver substantial actuating force. They can control large-diameter valves and enable precise regulation of flow in pipelines, making them particularly well-suited for applications involving large-diameter piping or where flow‑rate adjustment is required.

Solenoid valves are actuated by electromagnetic coils, which generate relatively low driving force and are therefore susceptible to damage from voltage surges. They are typically suitable for pipelines with nominal diameters of DN50 and smaller. They feature short actuation times during switching, and specialized high‑frequency solenoid valves are available, making them particularly well suited for applications involving frequent cycling or stringent requirements for rapid on/off response.

Solenoid valves are suitable for a wide range of media, including acids, alkalis, water, gases, oils, and steam. However, they impose stringent requirements on the viscosity and cleanliness of the fluid; therefore, a filter must be installed upstream of the solenoid valve to ensure its proper operation, low leakage rates, and high safety.

V. Technical Specifications of the Solenoid Valve
Solenoid valve

1. Water immersion

The inlet valve is immersed in water at a depth of 10 ± 1 cm and a temperature of 20 ± 5°C for 8 hours. After removal, the surface is wiped dry to eliminate any residual water droplets, and the insulation resistance shall be greater than 10 MΩ.

2. Temperature changes

The inlet valve is held at 80 ± 2°C for 1.5 minutes, then at room temperature (20 ± 2°C) for 1.5 minutes; a cycle consists of exposure at −20 ± 2°C for 30 minutes.

3. Durability

The inlet valve was subjected to water pressures of 0.02, 0.3, and 0.78 MPa at its inlet, while the coil was operated at its rated voltage for 5 seconds on and 5 seconds off, totaling 10,000, 30,000, and 10,000 cycles, respectively, after which it met the required specifications.

4. Noise

The inlet valve is not supplying water; when the rated voltage is applied, the sound power level measured at a distance r of 0.5 m is 50 dB.

5. Continuous power supply

With the inlet valve de-energized and subjected to its rated voltage for 12 hours, the valve body exhibits no deformation and shows no signs of burnout.

6. Interlayer Insulation

Under conditions of a peak voltage of 1500 V, a repetition rate of 25 Hz, a pulse rise time of 0.2–3 µs, and a pulse width of 40 µs applied for 2 seconds, the waveform remained stable with no abnormalities observed.
Original article link: http://www.pikacn.com/news/201611/5326.html

7. Coil Temperature Rise

When the inlet valve is de-energized, the coil is supplied with its rated voltage; after the temperature stabilizes, the coil temperature rise is less than 70 K.

8. Electrical Strength

The conductive and non-metallic parts shall be subjected to AC 2500 V for 1 minute, with no flashover or breakdown.

9. Insulation Resistance

The insulation resistance between the conductive part and the non-metallic part is greater than 100 MΩ.

10. Water Pressure Resistance

Hydrostatic pressures of 0.02 MPa, 0.8 MPa, and 1.96 MPa were applied to the inlet ports, with no leakage observed over 1 minute, 1 minute, and 5 minutes, respectively.

11. Water Pressure Resistance

Hydrostatic pressures of 0.02 MPa, 0.8 MPa, and 1.96 MPa were applied to the inlet ports, with no leakage observed over 1 minute, 1 minute, and 5 minutes, respectively.

12. Starting Characteristics

A water pressure of 0.8 MPa is applied at the inlet, and the coil is energized with 85% of its rated voltage for on/off cycling; no abnormalities are observed.

13. Flow Range

Depends on the requirements (typically 0.35–35 L/min).

14. Insulation Class

E grade.

15. Operating Voltage Range

±15% of the rated voltage.

16. Operating Pressure Range

0.02–1.0 MPa (can also be configured as a non‑pressurized internal‑core valve upon request; such designs are typically used for vessel drain or outlet valves).

17. Rated Voltage

Depending on the requirements (typically DC 6 V, 12 V, 24 V, 110 V; AC 6 V, 12 V, 24 V, 110 V, 220 V).

VI. Meaning of Solenoid Valve Markings
Solenoid valve

The term “solenoid valve” (also known as an inlet valve, solenoid water inlet valve, water‑powered solenoid valve, water supply solenoid valve, or non‑pressurized drain solenoid valve, among others) refers to a device that uses electromagnetic actuation to control the flow of fluids. For example, the model designation “FCD‑270B” is described as follows.

1. The letter “B”

“B” is the internal identification number assigned by the manufacturing plant itself.

2. The number “270”

“270” denotes the relative angle between the outlet terminal (i.e., the connector that interfaces with an external circuit or power supply) and the water inlet. There are only four possible relative angles between the inlet of the solenoid valve and the outlet terminal: 0°, 90°, 180°, and 270°. The determination is made as follows: looking down at the coil with its center as the origin, the relative angle measured counterclockwise between the axis of the solenoid valve’s water inlet and the terminal—where the inlet faces toward you and the outlet also points toward you—is 0°; if the outlet points to the right, it is 90°; if it points outward, it is 180°; and if it points to the left, it is 270°.

3. The letter “D”

“D” stands for single‑port (indicating the number of outlets on the inlet solenoid valve: a single outlet is denoted by “D,” while two outlets are denoted by “S,” as in FCS‑0A, FPS‑180B, etc. Three or more outlets are indicated by a numerical designation, such as FP3‑180C, FC4‑0D, and so on. Currently, the maximum number of outlets available on the market is four, corresponding to FC4 or FP4).

4. The letter “C”

“C” stands for “vertical,” indicating that the inlet and outlet of the water‑inlet solenoid valve are at a right angle to each other. There are only two possible relative orientations for the inlet and outlet of a water‑inlet solenoid valve: vertical or parallel. A vertical configuration is denoted by the letter “C,” while a parallel configuration is denoted by the letter “P.” For example, F“C”D—270B corresponds to a vertical arrangement, whereas F“P”D—90A corresponds to a parallel arrangement.

5. The letter “F”

“F” stands for “valve”; all inlet water solenoid valves are named with “F” as the initial letter.

Recommended


The Yueqing City Federation of Trade Unions “Brings Blessings to Enterprises,” Filling Kangleda with Joy and Fulfillment


The event kicked off promptly in the company’s first-floor lobby, creating a warm and festive atmosphere. The program featured a variety of engaging activities, including a “Calligraphy Brings Blessings” exhibition, allowing employees to appreciate the charm of this traditional art form.

2026-08-26

Kangleda New Energy Hosts an Employee Birthday Celebration, Using “Small Ceremonies” to Create “Great Warmth”


To demonstrate the company’s commitment to employee well-being and strengthen team cohesion, Kangleda New Energy Co., Ltd. recently hosted a group birthday celebration for employees whose birthdays fell in January and February. Through a simple yet warm ceremony and thoughtful, practical gifts, the event helped employees feel the warmth of “home.”

2026-08-26

In 2025, Kangleda New Energy will shine at the China Household Electrical Appliances & Consumer Electronics Expo (Shanghai).


From March 20 to 23, 2025, the China Household Electrical Appliances & Consumer Electronics Expo (AWE2025) was successfully held at the Shanghai New International Expo Center. Kangleda New Energy made a stunning appearance under the theme “Smart Energy Empowering Future Living.”

2026-08-26

Online Message



We are committed to providing you with high-quality products and professional services. Please keep your phone accessible, and we will contact you as soon as possible. Thank you for your support!

%{tishi_zhanwei}%